TM-30 Rf and Rg: What They Tell You That CRI Does Not
TM-30 Rf and Rg: what the two TM-30 numbers mean, how to read them together, and why a high CRI does not guarantee either.
A strip can print “CRI 90” on its datasheet and still disappoint in person. The reds look flat, the skin looks pale, the merchandise looks duller than it did under the old lights — and the number on the box says nothing is wrong. That is the blind spot TM-30 was built to fix.
TM-30 Rf and Rg are the two headline numbers of ANSI/IES TM-30, the method for evaluating how a light source renders colour. In one sentence: Rf is the fidelity index — how closely colours match a reference light, on average; Rg is the gamut index — whether colours look more or less saturated than under that reference. TM-30 Rf and Rg are always reported together, because neither one is meaningful alone. This guide explains what each number measures, how to read them as a pair, and what to ask for before ordering.


What Is TM-30?
TM-30 is a method from the Illuminating Engineering Society (IES) for evaluating light source colour rendition. The current version is ANSI/IES TM-30-24. Where the familiar CRI method (CIE Ra) averages eight pastel test colours, TM-30 Rf and Rg are calculated from 99 colour evaluation samples drawn from real-world objects — skin tones, textiles, paints, plastics, printed materials, and natural objects.
The larger sample set is the point. Eight muted pastels are easy to satisfy with a phosphor recipe that is weak exactly where it matters — deep reds, saturated greens, skin. Ninety-nine samples from real objects are harder to game, and they cover the colours a buyer actually judges.
Like Ra, TM-30 Rf and Rg compare the strip against a reference light at the same colour temperature — a black-body radiator below 5000K, a daylight phase above it. The reference is the “perfect” version of that white; the numbers say how close the strip gets, and in which direction it departs.
Rf: Fidelity, on a 0–100 Scale
Rf is the TM-30 fidelity index — the first of the two numbers in TM-30 Rf and Rg. It measures the average similarity between the appearance of the 99 evaluation samples under the test strip and their appearance under the reference light. A value closer to 100 means higher average fidelity: colours look more like they would under the reference.
Rf lands in a similar range to Ra, so an Rf of 90-plus carries roughly the meaning buyers expect. Ra 90 is the common expectation where colour is part of the product: clothing, cosmetics, food, galleries, premium interiors. An Rf in the same range means the same thing, earned against 99 samples instead of eight.
Two cautions belong with Rf. First, Rf is still an average — it cannot show which particular colours differ. A strip can score Rf 88 and still render one colour family badly. Second, Rf and Ra cannot be compared or swapped: different sample sets, different colour spaces, so an Rf of 85 is not “worse than” an Ra of 90. Ask for both, and read each on its own terms.
Rg: Gamut, or How Saturated Colours Look
Rg is the TM-30 gamut index. It describes the average change in chroma — saturation — of the test colours compared with the reference. The reading of TM-30 Rf and Rg is simple:
| Rg value | What it means |
|---|---|
| Rg ≈ 100 | Colours are about as saturated as under the reference light |
| Rg > 100 | Colours are enriched — more saturated, more vivid than the reference |
| Rg < 100 | Colours are dulled — less saturated than the reference |
Neither direction is automatically wrong. A slight enrichment can flatter merchandise on a retail shelf; a fidelity-driven gallery brief may want Rg close to 100. But you can only choose if the data is reported — and Rg is the number that tells you the direction.
Rg is also an overall measure: it says the average gamut expanded or contracted, but not which hue regions changed. A strip at Rg 105 might enrich reds and dull blues, and the single number hides the split. For that, the report has a third element: the colour vector graphic.
Reading TM-30 Rf and Rg Together
TM-30 Rf and Rg are a pair, and the pair is read as a combination. Four common combinations:
| Rf | Rg | How to read it |
|---|---|---|
| 90+ | 95–105 | Faithful and neutral — the colour-critical combination, for galleries, healthcare, and premium retail |
| 90+ | 105–115 | Faithful and vivid — colours are true and slightly enriched, a common retail preference |
| 80–90 | 100–115 | Good enough and pleasing — acceptable for general commercial work where “pleasing” matters more than accuracy |
| Below 80 | Any | Check the colour vector graphic before specifying — something specific is being lost |
The ranges reflect the specification frameworks in the standard’s annex: a fidelity priority (Rf ≥ 85, Rg 95–105) for spaces requiring accurate colour, and a preference priority (Rf ≥ 78, Rg 100–115) where pleasing colour matters more than accuracy. Healthcare and clinical work sit at the stricter end — Rf ≥ 90, Rg 97–103 — because skin tone fidelity is critical there.
The practical point: do not specify TM-30 Rf and Rg by one number alone. A buyer who asks only for “Rf 90” can receive a strip that is faithful on average and dull in the reds. The two numbers together, plus the vector graphic, are the specification.
The Colour Vector Graphic: Where the Averages Hide
The colour vector graphic is the part of a TM-30 report that settles arguments. It divides the colour space into 16 hue-angle bins, each representing a range of similar hues, and plots how the strip moves colours in each bin relative to the reference.
On the graphic, a black circle is the reference light and a red shape is the test strip. Where the red shape extends beyond the black circle, colours in that hue range look more saturated; where it falls inside, they look muted. Arrows show the direction: outward means more saturation, inward means less, and a rotation means the hue itself has shifted.
This is where the averages stop hiding things. Skin tones sit in the first two and last two hue bins, so a gallery or hospitality buyer can check those bins instead of trusting the average. A retail buyer can see whether the reds — where cheap phosphor recipes save money — are enriched or dulled. A museum buyer can see whether the whole shape stays close to the black circle.
If a supplier sends you a TM-30 report, ask for the colour vector graphic with it, not just the two numbers. TM-30 Rf and Rg summarise overall performance; the graphic shows the pattern.
Why Ra Can Be High and Rf Lower
The most common surprise in a TM-30 report is a strip with Ra 90 and Rf in the low 80s. It is the sample sets doing different jobs.
Ra averages eight pastel test colours (R1–R8) — all relatively muted, evenly spread across the hues. A strip can score Ra 90 while rendering one important colour family badly, as long as the other seven compensate.
Ra deliberately excludes the saturated test colours, including R9, the deep saturated red behind skin, food, and red merchandise. R9 can be low, zero, or even negative while Ra still prints a respectable number — the most common reason a “high CRI” installation disappoints. For colour-critical retail and hospitality work, R9 of 50 or higher is a common requirement, asked for separately because it is not part of the Ra average.
TM-30 Rf and Rg use 99 samples that include saturated colours and real objects, so the weaknesses Ra averages away are counted. A phosphor recipe that is thin in the reds will show up in Rf, in the red hue bins of the vector graphic, and in Rg if the gamut contracts there. That is why TM-30 is increasingly the standard request among professional lighting designers, even while CRI remains the common figure on household products.
Ra is still a useful first filter — Ra 80 for general commercial spaces, Ra 90 where colour matters. For a colour-critical project, specify Ra, R9, and TM-30 Rf and Rg together, and confirm them with a sample under your own materials.
How to Ask for TM-30 Before Ordering
Ask for the TM-30 report, not just TM-30 Rf and Rg. A complete request has four parts:
- Rf and Rg at each CCT you will use. On a tunable white strip, performance varies across the tuning range — a strip can render beautifully at 3000K and noticeably worse mid-blend, where two LED channels mix. Request values at both endpoints and at a mid-blend.
- The colour vector graphic. It shows which hue regions shift, and it is the part that catches a weak red or a dull blue that the averages hide.
- The R9 figure alongside. TM-30 Rf and Rg do not replace R9 — R9 is the separate check on saturated red, and it belongs on the specification as its own line item.
- The photometric report behind the figures. Datasheet numbers should trace to a measurement for the exact model and colour temperature.
HST’s TM-30 values are to be confirmed per model — we do not publish figures we have not measured. What we target for museum work: our museum LED strip is designed for CRI 97+ with near-zero UV below 400 nm — both design targets, to be confirmed per project — and R9 above 90 needs custom LED selection, also confirmed per project; our free-cut COB strip is Ra above 90. Send us your targets with your CCT range, and we will confirm what fits. For the background, see our guide to CRI, Ra, R9 and TM-30 on tunable white strips.
Frequently Asked Questions
What is a good TM-30 Rf value?
Rf is the fidelity index, on a 0–100 scale; closer to 100 means colours match the reference more closely. As a guide, Rf 90-plus is high fidelity, and the standard’s annex sets a fidelity priority of Rf ≥ 85 with Rg 95–105 for colour-critical work such as galleries and healthcare. Always read TM-30 Rf and Rg together — Rf alone cannot tell you whether colours are enriched or dulled.
What does Rg tell me that Rf does not?
Rg is the gamut index: whether colours look more or less saturated than under the reference light. Rg near 100 means about as saturated as the reference; above 100 they are enriched, below 100 they are dulled. Rf measures how close colours are to the reference on average, but not the direction of the saturation change — that is what TM-30 Rf and Rg add as a pair.
Does a high CRI guarantee a high Rf?
No. Ra averages eight pastel test colours, while TM-30 Rf and Rg are calculated from 99 samples drawn from real-world objects, including saturated colours Ra never tests. A strip can be Ra 90 and still score Rf in the low 80s if it is weak in the reds. Specify Ra, R9, and TM-30 Rf and Rg together for colour-critical work.
How do I get TM-30 data for a strip?
Ask the supplier for the TM-30 report: Rf, Rg, and the colour vector graphic, measured at each colour temperature you will use. HST’s TM-30 values are to be confirmed per model — send us your Rf, Rg, and R9 targets with your CCT range, and we will confirm what fits before you order.
Talk to Us
Colour rendering is judged on your materials, not on a datasheet. If your project is colour-critical — retail, hospitality, gallery, museum, or any space where skin, food, or merchandise is judged under the light — tell us the CCT range and the targets you need: Ra, R9, and TM-30 Rf and Rg. A sample under your own finishes will settle the rest. Browse our museum LED strip or contact us with your specification.